| Dimensions |
147(L) x 87(W) x 42(H) mm |
| Power & Temperature Display |
30~800W/ -9 °C~+99 °C |
| Fan Compatibility |
1 x 4-Pin (Supports fans with PWM function) |
| 3 x 3-Pin (Supports fans with RPM output function) |
| Fan RPM Control |
60~5,940rpm |
PWM Regulation Method (Fan No.4) |
| Voltage Control Method (Fan No.1~3) |
| Output Current |
0.7A |
| Output Voltage |
+4~11VDC |
| Input Voltage |
+12VDC/+5VDC |
| |
Graphic Power Load Meter: Displays power between 30 to 800W in 4 stages. |
|
| |
Numeric Power Load Display: Numerically displays power between 30 and 800W.
(The Numeric Power Load Display will read “LLL”when an overflow occurs. “LLL”indicates power loads beyond the unit’s measurable range.) |
|
| |
Fan Status Display: The Fan’s operation status is indicated with animated propeller images. |
|
| |
Fan Channels |
|
| |
RPM Display: During RPM Setting, RPM is displayed in units of 60RPM, and actual operational RPM is displayed in units of 10RPM. |
|
| |
Temperature Display: Displays temperature readings between -9 °C and +99 °C |
|
| |
Jog Wheel: Used for adjusting Fan RPM. RPM can be set from 1000 to 5940RPM in units of 60RPM. |
|
| |
Mode Button: Used for selecting a Fan Channel and saving the Fan RPM setting. |
|
Four channels of ZM-MFC2 detect fan RPM signals.
- The Alarm will activate if a fan is not connected or if there is no RPM input signal for any of the channels.
- To deactivate the Alarm, the Stand-By Mode (default setting: ON) of each unused channel must be deactivated. |
| |
| |
Selecting a Channel/Deactivating Stand-By Mode
(1) Select a channel with the Mode Button (The selected channel will begin to flicker).
(2) Press the Jog Wheel to deactivate the selected channel’s Stand-By Mode. The fan image will turn off.
(3) Deactivate the Stand-By Mode of all unused channels as mentioned above.
Note: Deactivating the Stand-By Mode of all the channels will not deactivate other functions (Channel Output, RPM Display, RPM Setting & Saving etc.) |
|
| |
RPM Setting and Saving
(1) Select a channel with the Mode Button.
(2) Set the RPM with the Jog Wheel. (Turning the Jog Wheel in clockwise motion will increase the RPM, and turning it counter-clockwise will decrease the RPM)
(3) Press the Mode Button again to save the set value and to select the next channel.
(If nothing is input for 5 seconds, the ZM-MFC2 will automatically save the latest setting and leave the Setting Mode). |
|
| |
Initializing to Default Settings
Press the Mode Button for 3 seconds. (The entire display will be on for 1 second and all fans will be set to 1500 RPM) |
|
- One ZM-MFC2
- One CVS (Current/Voltage Sensor)
- One Bracket/CVS Extension Cable
- Four Temperature Sensors
- Fan Cables : 3-Pin 1EA, 4-Pin 1EA, Y-Cable 1EA,
C3 Cable 1EA
- Four ZM-MFC2 Installation Bolts
- One Bracket Installation Bolts
- One User’s Manual
This product was added to our catalog on Friday 24 October, 2008.